Investigation Leader
To assist the Engineer in leak detection works, to supervise the Investigator and to prepare relevant records according to the prevailing guideline or as instructed by the Engineer.
Requirement
The Investigation Leader is required to be proficient at typing (in both Chinese and English) and operating computer system and shall have:
(i) A minimum of five (5) years of site experience in leading field working teams in conducting leakage detection work for water mains of all materials and sizes of pipes; and
(ii) A minimum of five (5) years of site experience in Leak Noise Correlators (LNC) surveys, Mechanical Leak Detectors (MLD) surveys, Electronic Leak Detectors (ELD) surveys, Hydrophones, pipe locator surveys, and other related surveys; and
(iii) Holding a valid “Certificate in Leak Detection on Water Mains" issued by the Hong Kong Institute of Construction (HKIC) or equivalent and having passed to the Engineer’s satisfaction a trial test arranged by the Engineer for testing the competence of the Investigation Leader.
Minimum Leakage Detection Survey Equipment shall be provided by the Investigator. Minimum Leakage Detection Survey Equipment shall be included, but not be limited to, the following items: LNC, MLD, ELD, Hydrophones, ground microphone, listening stick, noise loggers, pipe locators or as directed by the Engineer or his Representatives.
Investigator
To assist the Engineer in leak detection works, to carry out the LNC, MLD, ELD, Hydrophones and pipe locator surveys for the leakage detection work and to prepare relevant records according to the prevailing guideline or as instructed by the Engineer.
Requirement
The Investigation is required to be proficient at typing (in both Chinese and English) and operating computer system and shall have :
(i) A minimum of five (5) years of site experience in LNC surveys, MLD surveys, ELD surveys, Hydrophones, pipe locator surveys, and other related surveys; and
(ii) Holding a valid “Certificate in Leak Detection on Water Mains" issued by the Hong Kong Institute of Construction (HKIC) or equivalent and having passed to the Engineer’s satisfaction a trial test arranged by the Engineer for testing the competence of the Investigator.
Minimum Leakage Detection Survey Equipment shall be provided by the Investigator. Minimum Leakage Detection Survey Equipment shall be included, but not be limited to, the following items: LNC, MLD, ELD, Hydrophones, ground microphone, listening stick, noise loggers, pipe locators or as directed by the Engineer or his Representatives.
Applicants are required to send their full resume and expected salary by email to [our mailbox through CTgoodjobs Apply Now ] attention of Ms Edith Lee for interview. (All information received will be kept in strict confidential and only for employment related purposes)
Salary | |
Job Function | |
Location |
|
Work Model |
|
Industry | |
Employment Term |
|
Experience |
|
Career Level |
|
Education |
|
Wo Hing Construction Company Limited is a well-established civil engineering main contractor principally engaged in government projects. To cope with our expanding business, we are recruiting high-caliber individuals to work on a variety of utilities/infrastructure projects.